Steam Shower Installation: What to Plan Before You Build

Plan a steam shower before tile goes up: enclosure, vapor barrier, ceiling, generator location, power, steamhead and control placement, and permits.

Updated 2026-11-17 · GBC Kitchen & Bath

Glass-enclosed shower and soaking tub area with white subway tile and brushed bronze fixtures

Key Takeaway: A steam shower is built from the inside of the walls out. Before choosing tile, plan a fully enclosed and sealed space, a vapor barrier, a ceiling height and slope that suit the generator, a dry and accessible generator location, a dedicated 208 or 240 volt circuit, and the placement of the steamhead and control. Manufacturers differ on several of these details, so design to the manual for the generator you choose.

  • The enclosure, door and ceiling must hold steam; standard shower framing is not enough.
  • Generator size depends on room volume and construction, not only floor area.
  • ThermaSol and MrSteam give different steamhead and control heights.
  • Plan permits for the new plumbing and the dedicated electrical circuit.

A steam shower turns a bathroom into a personal steam room, but the parts that make it work are mostly hidden. Vapor behaves differently from shower water: it finds small gaps, rises to the ceiling and condenses on cool surfaces. That is why the planning order matters. Decisions about the enclosure, the ceiling and the generator need to be made before framing and waterproofing, not when tile samples arrive.

This guide pulls together planning guidance from two steam generator manufacturers, ThermaSol and MrSteam, and points out where they differ. When they differ, the instructions for the generator you buy should win. If you are still deciding whether steam is right for your home, see our steam shower page.

What Does a Steam Shower Need That a Regular Shower Does Not?

A regular shower manages water that runs down the walls. A steam shower must also manage vapor, heat and condensation. The table compares the two.

ElementRegular showerSteam shower planning guidance
EnclosureCan be open at the top or partly openFully enclosed, insulated and sealed, including the door frame (MrSteam)
Behind the finishWaterproofing for the wet zoneVapor barrier and/or waterproof material behind every surface (MrSteam FAQ)
Wall and ceiling surfacesMany tile and panel optionsNon-porous, heat-resistant materials such as tile or sealed natural stone (ThermaSol, MrSteam)
CeilingFlat is commonSloped to direct condensation, per ThermaSol and the MrSteam FAQ; height limited to suit the generator
LightingWet-location rated fixturesVapor-sealed fixtures inside the steam room (MrSteam)
HVACNot a concernNo heating, venting or air conditioning components inside the steam room (MrSteam)
EquipmentValve and shower headSteam generator, steam line, steamhead and control, plus a water line and drain
PowerUsually none for the shower itself208 or 240 volt circuit on a dedicated breaker
Steam shower planning checklist: enclosure, generator and power, and steamhead and control placement, with ThermaSol and MrSteam differences

How Should the Enclosure, Door and Ceiling Be Planned?

Start with containment. MrSteam’s planning page says the shower must be enclosed, insulated and sealed, and that any windows should be double-paned. Its construction FAQ adds that windows in the steam room should be tempered safety glass, and that the shower and door frame must be fully enclosed. A glass panel that stops short of the ceiling, or a door with open gaps, lets steam escape.

Door and glass. Plan a door and transom designed for steam. Our guide to frameless and framed shower doors explains how glass types, seals and hardware differ.

Ceiling height. MrSteam recommends limiting the steam room ceiling to about 8 feet. A taller ceiling is possible but needs a larger generator, and because steam rises, a high ceiling keeps the warm vapor above the person sitting below it. In a bathroom with a tall ceiling, the steam enclosure often gets its own lower ceiling.

Ceiling slope. ThermaSol recommends a slope of 1 to 2 inches per foot so condensation runs to the wall rather than dripping. MrSteam’s FAQ says the ceiling should be sloped, while its installation basics article says a slope is not needed unless sessions run longer than 45 minutes. Settle this with your designer and the generator manual before framing.

Ventilation outside sessions. ThermaSol recommends an exhaust fan or transom that lets steam escape after a session, as long as the opening can be sealed during use.

Where Should the Steam Generator Go?

The generator boils water and sends steam to the shower through a steam line. Both manufacturers allow it to sit away from the shower, but their limits differ.

Planning itemThermaSol guidanceMrSteam guidance
Distance from the showerUp to 50 feetUp to 60 feet (wired control)
Clearance around the unit6 inches12 inches
LocationClimate controlled and dry; level and correctly orientedDry and heated, such as a closet, vanity, heated attic or basement
SizingBy total cubic feet of the enclosureDepends on room size and construction; walls, ceiling height and windows change the size

Pick a spot your service technician can reach. MrSteam’s FAQ describes periodic draining of the generator, and our article on cleaning steam showers explains why generator care belongs on a separate checklist from glass and tile.

What Electrical and Plumbing Work Does a Steam Shower Need?

ThermaSol says steam generators typically need a 208 to 240 volt, single phase supply on a dedicated circuit breaker, and recommends a licensed electrician. MrSteam lists the same voltage range. The amperage and breaker size depend on the generator model, so choose the generator before the electrician sizes the circuit.

Plumbing includes a water supply line to the generator, a steam line from the generator to the shower, and a drain. MrSteam’s FAQ also calls for a floor drain in the steam room. A linear drain is one option; our guide to shower floor types covers how floor and drain choices affect slope and tile.

Where Do the Steamhead and Control Go?

This is where manufacturer guidance differs the most, so use the manual for your specific system.

ComponentThermaSol guidanceMrSteam guidance
Steamhead heightAt least 24 inches above the shower floorAbout 6 to 12 inches above the floor
Steamhead position6 inches from corners; not under benches or seating; on a different wall than the controlAway from the bather and opposite the seating area; on the wall opposite the control
Control height60 inches from the floor, near the bench or within reach4 to 5 feet above the floor near the bench (installation basics); 5 to 7 feet (construction FAQ)

The reason for keeping the control away from the steamhead is accuracy. MrSteam explains that the control contains a thermostat that would not read properly directly above the steamhead.

Thinking about a steam shower as part of a bathroom remodel? Contact us with your bathroom dimensions, ceiling height and photos of the room, and we can talk through the enclosure, generator location and layout.

Which Materials Suit the Inside of a Steam Shower?

ThermaSol recommends non-porous, heat-resistant materials, and notes that natural stone must be properly sealed. MrSteam’s FAQ lists tile, natural or man-made stone, molded acrylic and other non-porous materials for walls and ceilings, and advises checking material suitability with each manufacturer. MrSteam’s planning page adds that larger tiles collect less condensation.

A bench is common in steam showers. Both manufacturers place the steamhead away from seating, so decide where the bench goes before locating the steamhead.

Do You Need a Permit for a Steam Shower?

Usually yes, because a steam shower adds plumbing and a new electrical circuit. Fairfax County lists new or relocated plumbing fixtures and new electrical fixtures among work that requires permits, and a bathroom remodel itself falls under interior alterations. In Montgomery and Prince George’s counties, WSSC Water states that most plumbing work must be done by a plumber it licenses. Other counties and cities have their own offices, so confirm the permit path for your address before work begins.

What Should You Decide Before Tile Goes Up?

  1. Enclosure size, including the ceiling height inside the steam room
  2. Ceiling slope, based on the generator manual
  3. Door, transom and glass that seal fully
  4. Generator model and size, based on room volume and construction
  5. Generator location, distance and clearance, with service access
  6. Dedicated circuit sized for that generator
  7. Steamhead, control and bench positions
  8. Vapor barrier or waterproofing system and non-porous finishes
  9. Vapor-sealed lighting and any exhaust fan or transom for after sessions
  10. Permits for plumbing and electrical work

Planning a Steam Shower in Northern Virginia or Maryland?

See our bathroom remodeling service page for the bathroom work GBC Kitchen & Bath offers. When you are ready, contact us with your room measurements and the checklist above.

Showroom locations, as listed on the contact page:

  • Alexandria: 5601 General Washington Dr Unit H, Alexandria, VA 22312. Phone (703) 750-1188. Hours Monday to Friday 9 a.m. to 6 p.m., Saturday 10 a.m. to 4 p.m.
  • Rockville: 1055 Rockville Pike, Rockville, MD 20852. Phone (301) 309-3520. Hours Monday to Friday 9 a.m. to 5 p.m., Saturday 10 a.m. to 4 p.m.
  • Ashburn: 44031 Ashburn Shopping Plaza Suite 275, Ashburn, VA 20147. Phone (703) 520-7990. Hours Monday to Friday 9 a.m. to 6 p.m., Saturday 10 a.m. to 4 p.m.
  • Columbia: 9204 Berger Rd Ste E, Columbia, MD 21046. Phone (410) 417-6060. Hours Monday to Friday 9 a.m. to 5 p.m., Saturday 10 a.m. to 3 p.m.

Main phone: (844) 644-4422. Email: info@gbcdc.com.

Frequently Asked Questions

What do you need to install a steam shower?

You need a fully enclosed and sealed shower, a vapor barrier or waterproofing system behind the finish, non-porous wall and ceiling surfaces, a floor drain, a steam generator sized to the room, a water supply and steam line to the shower, and a dedicated electrical circuit. Manufacturers such as MrSteam and ThermaSol list these items in their planning guides. Because the work happens behind the tile, it is usually planned as part of a bathroom remodel.

Where should a steam shower generator be installed?

In a dry, heated, accessible location within the distance the manufacturer allows. ThermaSol says up to 50 feet from the shower with 6 inches of clearance, and MrSteam says up to 60 feet with 12 inches of space around the unit. Common spots include a vanity cabinet, a closet, a heated attic or a basement. Plan access for service, because the generator needs periodic draining or descaling under its manual.

Does a steam shower ceiling need to be sloped?

Usually, but manufacturers word it differently. ThermaSol recommends a slope of 1 to 2 inches per foot so condensation runs to the wall instead of dripping on bathers. MrSteam's construction FAQ says the ceiling should be sloped, while its installation basics article says a slope is not necessary unless sessions run longer than 45 minutes. Follow the instructions for the generator you choose, and decide before framing.

What electrical service does a steam generator need?

Most residential steam generators need 208 or 240 volt, single phase power on a dedicated circuit breaker, according to ThermaSol and MrSteam planning guides. The exact amperage depends on the generator model and size, which depends on the room volume and construction. A licensed electrician should size and install the circuit. In Fairfax County, new electrical work requires an electrical permit.

How high can a steam shower ceiling be?

MrSteam recommends limiting the steam room ceiling to about 8 feet; a taller ceiling is possible but calls for a larger generator, and steam rises, so a high ceiling leaves the warm vapor above the bather. ThermaSol sizes generators by the total cubic feet of the enclosure. If your bathroom has a tall or vaulted ceiling, plan a lower ceiling inside the steam enclosure.

Do I need a permit to add a steam shower?

Usually yes, because the work adds plumbing and electrical. Fairfax County lists new or relocated plumbing fixtures and new electrical fixtures among work that requires permits, and a bathroom remodel itself is listed under interior alterations. In Montgomery and Prince George's counties, WSSC Water states that most plumbing must be done by a plumber it licenses. Confirm the permit path with the office that covers your address.

Sources: ThermaSol: Steam Shower Design Tips·MrSteam: Plan Your Project·MrSteam: Steam Shower Construction FAQ·Fairfax County LDS: Does My Project Require a Permit?

products/steam showerblog/clean steam showersservices/bathroom remodelingblog/frameless vs framed shower doorsblog/common shower floor types their pros and conscontact

Let's Get Started

Tell us about your remodeling plans.

Start with a free in-home estimate for your kitchen or bathroom project, or visit one of our four showrooms to explore materials. We reply within one business day.

Prefer to see materials first? Find your nearest showroom

Kitchen & bath remodeling Visit our showrooms 3-year warranty